CN EN
CN EN

D3W Directional spool valve DIN NG10

D3W Directional spool valve DIN NG10

Design Directional spool valve
Actuation Solenoid
Size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTFD value [years] 150
Weight [kg] 4.8 (1 solenoid), 6.3 (2 solenoids)
Vibration resistance [g]
10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 210 (DC), 105 (AC)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm2/s] 2.8...400
Viscosity recommended [cSt] / [mm2/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 (DC); 115 (AC) (see shift limits)
Leakage at 50 bar [ml/min] Up to 20 per flow path, depending on spool
Static / Dynamic
Step response see table response times
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G Y T
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V =
110 V at 50 Hz/
120 V at 60 Hz
230 V at 50 Hz/
240 V at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 3 1.5 0.35 0.18 0.8 / 0.72 0.4 / 0.36
Current consumption in rush [A] 3 1.5 0.35 0.18 3.41 / 3.31 1.75 / 1.7
Power consumption hold [W] 36 36 34 36 88 / 86 88 / 86
Power consumption in rush [W] 36 36 34 36 375 / 397 385 / 408
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended

Description